Exhaust Gas Recirculation Valve Outlet Pipe Replacement for Buick Regal 2001
Removal Procedure
- If applicable, remove the secondary air injection (AIR) pump outlet
pipe. Refer to
Secondary Air Injection Pump Outlet Pipe/Hose Replacement
.
- Remove the mounting bolt (3)
that attaches the EGR outlet pipe flange to the intake manifold.
- Remove the nut (2) that attaches the EGR outlet pipe to
the EGR valve adapter pipe assembly.
- Remove the EGR valve outlet pipe (1).
Installation Procedure
- Install the EGR valve
outlet pipe (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install bolt (3)
to the intake manifold.
Tighten
Tighten the mounting bolt to 29 N·m (21 lb ft).
- Install retaining nut (2) to the EGR valve adapter pipe
assembly.
Tighten
Tighten the nut to 29 N·m (21 lb ft).
- If applicable, install the secondary air injection
(AIR) pump outlet pipe. Refer to
Secondary Air Injection Pump Outlet Pipe/Hose Replacement
.