Testing for Electrical Intermittents for Chevrolet Colorado Pickup - 4WD 2004
Special Tools
J 39200
Digital Multimeter
Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
If the fault is not identified, perform the procedure below using the MIN MAX feature on the
J 39200
DMM. This feature allows you to manipulate the circuit without having to watch the
J 39200
. The
J 39200
will generate an audible tone when a change is detected.
Note: The
J 39200
must be used in order to perform the following procedure since the
J 39200
can monitor current, resistance or
voltage while recording the minimum (MIN), and maximum (MAX) values measured.
- Connect the
J 39200
to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. Refer to
Troubleshooting with a Digital Multimeter for information on connecting the
J 39200
to the circuit.
- Set the rotary dial of the
J 39200
to the V (AC) or V (DC) position.
- Press the range button of the
J 39200
in order to select the desired voltage range.
- Press the MIN MAX button of the
J 39200
. The
J 39200
displays 100 ms RECORD and emits an audible tone (beep).
Note: The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
- Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or performing other operations. Refer to
Inducing Intermittent Fault Conditions.
- Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded.
- Press the MIN MAX button once in order to display the MAX value and note the value.
- Press the MIN MAX button again in order to display the MIN value and note the value.
- Determine the difference between the MIN and MAX values.
| • | If the variation between the recorded MIN and MAX voltage values is 1 V or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. |
| • | If the variation between the recorded MIN and MAX voltage values is less than 1 V, an intermittent open or high resistance condition does not exist. |