Air Inlet Valve Actuator Replacement for HUMMER H2 2007
Removal Procedure
- Remove the instrument panel (I/P) upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the screws from the recirculation actuator (1).
- Remove the recirculation actuator (1) from the HVAC module assembly (2).
Installation Procedure
- Install the recirculation actuator (1) to the HVAC module assembly (2).
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the recirculation actuator (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the recirculation actuator.
- Install the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
.
- Reprogram the recirculation actuator. Refer to
Actuator Recalibration
.