Air Inlet Valve Actuator Replacement for HUMMER H2 2008
Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the Inflatable Restraint I/P Module. Refer to
Inflatable Restraint Instrument Panel Module Replacement
.
- Disconnect
the electrical connection from the recirculation actuator (1).
- Remove
the recirculation actuator retaining screws.
- Remove the recirculation actuator.
Installation Procedure
- Install
the recirculation actuator.
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator retaining screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect
the electrical connector to the recirculation actuator (1).
- Install the Inflatable Restraint I/P Module. Refer to
Inflatable Restraint Instrument Panel Module Replacement
.
- Re-calibrate the recirculation actuator. Refer to
Actuator Recalibration
.