GM Service Manual Online
For 1990-2009 cars only

Scan Tool Output Controls for HUMMER H3 2007

Scan Tool Output Control

Additional Menu Selection(s)

Description

HVAC Fan Auto On

Outputs

When On is selected with the scan tool, the body control module (BCM) supplies a ground for coil of the ignition 3 relay (IGN 3) in the underhood bussed electrical center (UBEC), which supplies battery power to the blower motor and the HVAC control assembly. The blower motor switch must be in a speed position other than OFF for output to function. When OFF is selected with the scan tool, the BCM removes the ground for the IGN 3 relay and the blower motor is disabled.