Auxiliary Blower Motor Processor Replacement for Isuzu Ascender - 4WD 2004
Removal Procedure
- Remove the right rear quarter trim panel. Refer to
Rear Quarter Trim Panel Replacement - Right Side
in Interior Trim.
- Remove the HVAC module-auxiliary. Refer to
Auxiliary HVAC Module Replacement
in Heating, Ventilation and Air Conditioning.
- Disconnect the electrical connector from the blower motor processor.
- Remove the retaining screws from the blower motor processor (1).
- Remove the blower motor processor (3) from the HVAC module (2).
Installation Procedure
- Install the blower motor processor (3) to the HVAC module (2).
Notice: Refer to Fastener Notice in the Preface section.
- Install the retaining screws to the blower motor processor (3).
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the HVAC module-auxiliary. Refer to
Auxiliary HVAC Module Replacement
in Heating, Ventilation and Air Conditioning.
- Connect the electrical connector to the blower motor processor (1).
- Install the right rear quarter trim panel. Refer to
Rear Quarter Trim Panel Replacement - Right Side
in Interior Trim.