Air Conditioning (A/C) High Pressure Switch Replacement for Isuzu Isuzu MD F-Series 2007
Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
- Tilt the cab forward. Refer to
Cab Tilting
.
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the A/C high pressure switch electrical connector (2).
- Remove the A/C high pressure switch from the receiver dehydrator.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the A/C high pressure switch to the receiver dehydrator.
Tighten
Tighten the switch to 6 N·m (53 lb in).
- Connect the A/C high pressure switch electrical connector (2).
- Evacuate and recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fitting of the component using the
J 39400-A
.
- Lower the cab. Refer to
Cab Tilting
.