Air Inlet Actuator Replacement for Oldsmobile Intrigue 2000
Removal Procedure
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges and Console.
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console
- Remove the vacuum electrical solenoid. Refer to
Vacuum Electrical Solenoid Replacement
in Manual HVAC Systems
or
Vacuum Electrical Solenoid Replacement
in Automatic HVAC Systems.
- Disconnect the vacuum line from the air inlet vacuum actuator.
- Lift to release the air inlet vacuum actuator retaining tab and
slide off mounting bracket.
- Disconnect the vacuum
actuator plunger rod from the air inlet valve lever and remove the air inlet
vacuum actuator.
Installation Procedure
- Connect the air inlet
vacuum actuator plunger rod to the air inlet valve, then extend the plunger.
Important: During installation, ensure that the air inlet vacuum actuator retaining
tab is positioned above the mating base on the HVAC control module case.
- Push the vacuum actuator toward the HVAC control module case to secure
the retaining tab.
Important: Check that the vacuum actuator pushrod is not binding on the air inlet
lever.
- Connect the vacuum harness connector to the air inlet vacuum actuator.
- Install the vacuum electrical solenoid. Refer to
Vacuum Electrical Solenoid Replacement
in Manual HVAC Systems or
Vacuum Electrical Solenoid Replacement
in Automatic
HVAC Systems.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console.