Evaporative Emission Canister Vent Solenoid Valve Replacement for Pontiac G6 2007
Removal Procedure
- Lower the fuel tank enough on the right side in order to access the evaporative emission (EVAP) canister vent
solenoid valve. Refer to
Fuel Tank Replacement. It is not necessary to completely remove the fuel tank from the vehicle.
- Disconnect the EVAP canister vent solenoid valve tube quick connect fitting (2). Refer to
Plastic Collar Quick Connect Fitting Service.
- Disconnect the EVAP canister vent solenoid valve electrical connector (2).
- Disconnect the EVAP canister vent tube quick connect fitting (1). Refer to
Plastic Collar Quick Connect Fitting Service.
- Depress the locking tab on the EVAP canister vent solenoid valve mount and slide the valve rearward off of the fuel tank.
Installation Procedure
- Install the EVAP canister vent solenoid valve onto the mount on the fuel tank, push the valve forward until
the locking tab engages.
- Connect the EVAP canister vent tube quick connect fitting (1). Refer to
Plastic Collar Quick Connect Fitting Service.
- Connect the EVAP canister vent solenoid valve electrical connector (2).
- Connect the EVAP canister vent solenoid valve tube quick connect fitting (2). Refer to
Plastic Collar Quick Connect Fitting Service.
- Raise the fuel tank completely on the right side. Refer to
Fuel Tank Replacement.