Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement for Pontiac Montana Ext. 2003
Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Remove the air baffle
bolts.
- Remove the air baffle.
- Disconnect the A/C refrigerant
pressure sensor electrical connector.
- Remove the A/C refrigerant pressure sensor from the evaporator
inlet tube.
Installation Procedure
- Using a lint-free clean, dry cloth, carefully clean the sealing
surfaces of the evaporator inlet tube fitting.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant
oil on the O-ring seal to enter the refrigerant system.
- Lightly coat the O-ring seal with mineral base 525 viscosity
refrigerant oil.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the A/C refrigerant pressure sensor to the evaporator inlet
tube.
Tighten
Tighten the sensor to 5 N·m (44 lb in).
- Connect the A/C refrigerant pressure sensor electrical connector.
- Leak test the fittings of the component using J 39400-A
.
- Install the air baffle.
- Install the air baffle bolts.
Tighten
Tighten the bolts to 20 N·m (15 lb ft).
- Lower the vehicle.